Cookie Img Back to top
Send SMS    Call Me Free Offline
+917259683083
                            Home » Products » Control Panel » Domestic Heating System Control Training Panel

                            Domestic Heating System Control Training Panel

                            Domestic Heating System Control Training Panel
                            Domestic Heating System Control Training Panel
                            Product Code : Heating Panel
                            Product Description

                            Domestic Heating Circuit Training Panel

                            Technical Description of Domestic Heating Circuit Training Panel

                            A pump circulates water through four radiators. The temperature of the radiators is set using thermostatic valves. A digital controller keeps the room temperature constant by driving the four-way mixing valve. This valve sets the temperature of the boiler return flow and the feed flow. Cold water connections enable the heat generated to be dissipated. The differential pressure across the pipe system is limited using a relief valve. Temperatures can be read on dial thermometers.

                            Specification of Domestic Heating Circuit Training Panel

                            • Trainer for heating engineering
                            • Heating controller with feedback of the feed flow temperature
                            • 4-way mixing valve DN 20
                            • Circulating pump
                            • 7 Rotameters
                            • 4 Plate heat exchangers as radiators
                            • 5 Bimetallic dial thermometers
                            • 2 Cold water connections DN 15
                            • 2 Water connections for boiler DN 15
                            • 1 Differential pressure overflow valve 

                            Technical Data of Domestic Heating Circuit Training Panel

                            Pump

                            • Power consumption: 60W
                            • Max. Flow rate: 60L/min
                            • Max. Head: 4m 

                            Radiator

                            • Plate heat exchanger with 8 plates
                            • Capacity: 3kW 

                            Heating controller with feedback of the feed flow temperature

                            • Inputs: 2 temperature sensors

                            Measuring ranges

                            • Temperature: 0...100°C
                            • Flow rate: 2x 150...1600L/h, 1x 0...1000L/h,
                            • 4x 0...400L/h

                            Dimensions and Weight of Domestic Heating Circuit Training Panel

                            • l x w x h: 1850 x 400 x 1150 mm (panel)
                            • Weight: approx. 90 kg (panel)

                            MAVEN AUTOMATION

                            Contact Us

                            ( *represents compulsory fields )

                            Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.