                Product Description

                Domestic Heating Circuit Training Panel

                Technical Description of Domestic Heating Circuit Training Panel

                A pump circulates water through four radiators. The temperature of the radiators is set using thermostatic valves. A digital controller keeps the room temperature constant by driving the four-way mixing valve. This valve sets the temperature of the boiler return flow and the feed flow. Cold water connections enable the heat generated to be dissipated. The differential pressure across the pipe system is limited using a relief valve. Temperatures can be read on dial thermometers.

                Specification of Domestic Heating Circuit Training Panel

                • Trainer for heating engineering
                • Heating controller with feedback of the feed flow temperature
                • 4-way mixing valve DN 20
                • Circulating pump
                • 7 Rotameters
                • 4 Plate heat exchangers as radiators
                • 5 Bimetallic dial thermometers
                • 2 Cold water connections DN 15
                • 2 Water connections for boiler DN 15
                • 1 Differential pressure overflow valve 

                Technical Data of Domestic Heating Circuit Training Panel

                Pump

                • Power consumption: 60W
                • Max. Flow rate: 60L/min
                • Max. Head: 4m 

                Radiator

                • Plate heat exchanger with 8 plates
                • Capacity: 3kW 

                Heating controller with feedback of the feed flow temperature

                • Inputs: 2 temperature sensors

                Measuring ranges

                • Temperature: 0...100°C
                • Flow rate: 2x 150...1600L/h, 1x 0...1000L/h,
                • 4x 0...400L/h

                Dimensions and Weight of Domestic Heating Circuit Training Panel

                • l x w x h: 1850 x 400 x 1150 mm (panel)
                • Weight: approx. 90 kg (panel)